E. Sunderland, "Automatic fault monitoring and restart procedure on the SRC Atlas", 16th February 1968.

  • Reference
    • GB 133 ESF/42
  • Dates of Creation
    • 1968
  • Physical Description
    • 11 sheets

Scope and Content

11 typed pages, approx. A4 in size. Informative technical description of mechanisms for automatic and manual restart after a fault has been detected and how to interpret the fault print-out and post-mortem data.